DNX and DNXC Current-Limiting Capacitor Fuses, 2.8kV to 38kV
DNX fuses are DENCO's current-limiting, clip-style capacitor fuses, rated 2.8kV to 38kV and 1C to 140C with a 50kA interrupting rating. DNXC fuses are full-range, current-limiting capacitor fuses for bus bar to lead mounting, rated 8.3kV to 23kV and 10A to 65A at 50kA. A DNX fuse melts in 1000 seconds at 1.7 to 2.4 times its C number.
Request a quoteCross-reference a partAccess the catalog
DNX catalog numbers carry the voltage class and C range: DNX2 at 2.8kV, DNX4 at 4.3kV, DNX5 at 5.5kV, DNX8 at 8.3kV, DNX15 at 15.5kV, DNX23 at 23kV and DNX27 at 27kV, with a 38kV size above that. Each voltage is split into two or three C ranges, for example DNX8-1C to 12C, 15C to 40C and 50C to 140C. The body diameter listed is a maximum, and threaded end studs are also available.
DNXC fuses are listed by individual rating, from DNXC8-10 to DNXC23-25, with an approximate weight for each. They were tested at IPH to IEC 60282-1: 2009-10 and IEC 60282-2: 2008-04. The catalog requires temperature derating when a DNXC fuse runs in ambient conditions above 25°C, using the printed formula based on the maximum ambient the fuse will see.
Specifications
| Parameter | Value |
|---|---|
| DNX voltage range | 2.8kV to 38kV |
| DNX current range | 1C to 140C |
| DNX interrupting rating | 50kA asymmetrical |
| DNX 2.8kV | 1C to 45C and 50C to 100C |
| DNX 4.3kV | 18C to 35C and 40C to 100C |
| DNX 5.5kV | 6C to 18C and 20C to 75C |
| DNX 8.3kV | 1C to 12C, 15C to 40C, 50C to 140C |
| DNX 15.5kV | 1C to 4.5C, 6C to 40C, 50C to 140C |
| DNX 23kV | 3C to 40C and 50C to 140C |
| DNX 27kV and 38kV | 6C to 50C |
| DNX melting characteristic | Melts in 1000 s at 1.7 to 2.4 times the C number |
| DNXC voltage and current | 8.3kV to 23kV, 10A to 65A |
| DNXC interrupting rating | 50kA |
| DNXC 8.3kV ratings | 10, 18, 25, 30, 40, 45, 65A |
| DNXC 23kV ratings | 12, 18, 25A |
| DNXC mounting | Bus bar to lead |
Construction and options
- DNX: clip style
- DNX: threaded end studs also available
- DNX: listed body diameter is a maximum
- DNXC: full-range current-limiting
- DNXC: temperature derating above 25°C ambient
- DNXC: approximate weight listed per part
Catalog numbers in this series
| Catalog no. | Availability | Last reviewed |
|---|---|---|
| DNXC8-10 | Active | 2026-08-27 |
| DNXC8-18 | Active | 2026-08-27 |
| DNXC8-25 | Active | 2026-08-27 |
| DNXC8-30 | Active | 2026-08-27 |
| DNXC8-40 | Active | 2026-08-27 |
| DNXC8-45 | Active | 2026-08-27 |
| DNXC8-65 | Active | 2026-08-27 |
| DNXC15-10 | Active | 2026-08-27 |
| DNXC15-12 | Active | 2026-08-27 |
| DNXC15-18 | Active | 2026-08-27 |
| DNXC15-25 | Active | 2026-08-27 |
| DNXC15-30 | Active | 2026-08-27 |
| DNXC15-35 | Active | 2026-08-27 |
| DNXC15-40 | Active | 2026-08-27 |
| DNXC23-12 | Active | 2026-08-27 |
| DNXC23-18 | Active | 2026-08-27 |
| DNXC23-25 | Active | 2026-08-27 |
Standards and equivalents
- DNXC tested at IPH, IEC 60282-1: 2009-10 & IEC 60282-2: 2008-04
Wording is the catalog’s own. “In accordance with” a standard is not the same as certified or listed to it.
Curves and drawings
The catalog prints the following for this series: dnxc time-current curves (p.73), dnxc dimension drawing, bus bar to lead mounting (p.74). This series is on pp.72–74 of the January 2025 DENCO catalog. Access the catalog or ask for the drawing or curve you need.
Technical review
Specifications on this page are quoted from DENCO’s product catalog. Confirm any rating against DENCO engineering before specifying.
Related
- C-Rated Capacitor Protection Fuses: the full family
- Capacitor protection fuses Types 1 to 9, 1kV to 5.5kV
- All fuse product families
- Cross-reference and discontinued replacement